+86 15019442144 ( WhatsApp / WeChat ) info@zerouno-lighting.com
Quality Assurance

Our Test Lab

Sixteen instruments. Five disciplines. One roof — so the performance we quote is the performance we ship.

In-House By Design

We don’t estimate performance. We measure it.

In 2026 we commissioned a dedicated test laboratory at our Zhongshan factory. The equipment covers photometry and colour, electrical safety, driver and battery behaviour, reliability and aging, and environmental and transport durability — the five areas that decide whether a luminaire survives a hotel installation.

The laboratory is used for design verification on new developments, inspection of incoming drivers, LED boards and battery packs, and pre-shipment batch control on finished goods. Results are recorded against the order, so a specifier can see how the actual production units performed — not how a hand-built sample performed.

16Test instruments installed in house
5Test disciplines under one roof
380–780 nmSpectral range of colour measurement
1,500 mmMaximum drop-test height, up to 80 kg
Test Capabilities

Five disciplines, under one roof.

Every instrument below is installed at our Zhongshan factory. Together they follow a product from an incoming driver to a packed export carton.

01

Photometric & Colour Measurement

A 2 nm bandwidth CCD spectrometer covering 380–780 nm reports the numbers a lighting designer actually works with.

  • Correlated colour temperature, 1,000–100,000 K
  • Colour rendering index (CRI / Ra)
  • Chromaticity coordinates and SDCM colour tolerance
  • Illuminance 0.1 lx – 200 klx, spectral distribution
02

Electrical Safety

Insulation, dielectric strength, leakage and earthing verified on assembled luminaires and drivers.

  • Insulation resistance 10 V–1,000 V, 1 × 105 to 1 × 1011 Ω
  • Dielectric withstand (hipot) testing
  • Leakage current measurement
  • Earth / ground continuity
03

Driver, Power & Battery

The electronics side of a luminaire, tested at the values the project will actually run at.

  • Driver output voltage, current and power
  • 50 Hz and 60 Hz operation, brown-out and over-voltage response
  • Battery discharge capacity and internal resistance
  • Over-charge, over-discharge, over-current and short-circuit protection
04

Reliability, Aging & Thermal

Stress applied before shipment, so early-life failures happen here instead of on site.

  • Programmable high–low voltage impulse aging
  • 16-channel temperature rise logging, −200 to 1,250 °C at 0.01 resolution
  • Stability test bench for free-standing luminaires
05

Environmental & Transport

Finish performance and packaging protection for coastal projects and long-haul shipping.

  • NSS, ACSS and CASS salt spray corrosion testing
  • Face, edge and corner free-drop testing
  • Drop height 300–1,500 mm, specimen up to 80 kg
Inside The Lab

The room behind the numbers.

Every instrument on this page — and the mechanical and surge stations working alongside them — sits in our own facility in Zhongshan. These are the actual benches.

Four views of the ZEROUNO aging test area: luminaire aging racks, the wide test floor, LED modules under power and rack wiring
Stress Before Shipment

We age it, cycle it and heat it — so your site doesn’t have to.

Most failures in a hospitality lighting project show up in the first weeks: a driver that cannot hold at a low mains voltage, a thermal hot spot inside a sealed head, a battery pack that trips on over-current after twenty cycles.

The high–low voltage impulse aging controller runs finished luminaires through repeated supply swings, while the DC6016 logger tracks sixteen thermocouple channels across drivers, LED boards and heat sinks. The stability bench then confirms that a free-standing luminaire will not topple at the specified angle.

16 thermocouple channels · K / T / J / S types · live values, temperature-rise values and real-time curves logged to USB

Equipment Inventory

What is in the lab.

Sixteen instruments, listed with what each one actually verifies in our production.

Instrument What it verifies in our production
HPS200 Handheld Spectral Color Illuminance Meter CCT, CRI, chromaticity coordinates, SDCM colour tolerance, illuminance and spectral distribution
DC2679E Programmable Insulation Resistance Tester Insulation resistance of luminaires and drivers, before and after aging
Dielectric Withstand (Hipot) Tester Dielectric strength, leakage current and earth continuity on assembled fittings
Digital Multimeter Voltage, current, resistance and capacitance for assembly checks and fault finding
DC6016 Multi-Channel Temperature Logger Temperature rise on drivers, LED boards and heat sinks; instrument range −200 to 1,250 °C, 0.01 resolution, K-type thermocouples supplied
ZLT-WD1 Stability Test Bench Toppling resistance of floor and table luminaires at the specified tilt angle
Salt Spray Test Chamber (60A) NSS, ACSS and CASS corrosion resistance of plated, painted and anodised finishes
Single-Arm Drop Test Machine Face, edge and corner drops; packaging protection under transport shock
Seven-Meter High-Precision Test Bench Driver output voltage, current and power measured against specification
Adjustable DC Power Supply Low-voltage LED board function and current draw
Variable Frequency AC Power Source Operation on 50 Hz and 60 Hz supplies; power consumption verification
Variable Transformer (Variac) Driver start-up and hold at low and high mains voltage; aging power supply
Programmable Battery Comprehensive Tester Battery discharge capacity and internal resistance; driver output-side parameters
Battery Comprehensive Tester Battery voltage and internal resistance; over-charge, over-discharge, over-current and short-circuit protection
High-Low Voltage Impulse Aging Test Control Box Driver endurance under repeated mains voltage swings; early-life failure screening
USB Power Tester USB charging voltage, current and power; cumulative energy and charge capacity
Test Methods & Standards

Methods that trace back to published standards.

Where a published method exists for a test we run, our parameters are configured to it.

01

Photometric & colour measurement

CCT, CRI / Ra, chromaticity coordinates, SDCM and illuminance measured with a 2 nm bandwidth CCD spectrometer over 380–780 nm.

02

Dielectric withstand, insulation & earthing

Dielectric strength, leakage current and earth continuity verified on assembled luminaires, drivers and metal-bodied fittings.

03

Thermal & temperature rise

Sixteen-channel K-type thermocouple logging at 0.01 resolution, recording live values, temperature-rise values and real-time curves.

04

Corrosion (salt spray)

NSS, ACSS and CASS cycles; chamber at 35 ±1 °C and CASS at 50 ±1 °C with a 47 ±1 °C air saturator, parameters set to JIS, ASTM, CNS and GB standard values.

05

Transport packaging drop

Face, edge and corner free-drop tests with encoder-verified drop height, configured to ISO 2248, JIS Z 0202-87 and GB/T 4857.5-92.

06

Voltage stress & battery protection

Programmable high–low voltage impulse cycling in automatic and manual modes, plus battery over-charge, over-discharge, over-current and short-circuit threshold testing.

Scope of this laboratory. The equipment above supports our design verification, incoming material inspection and pre-shipment batch control. Certification and project submittal reports that must be issued by an accredited body are arranged with independent third-party laboratories — the in-house laboratory is what lets us find a problem before a third-party test is ever scheduled.
Where It Sits In Your Order

Five checkpoints between your specification and your shipment.

Incoming componentsDrivers, LED boards, battery packs and finishes are screened when they arrive, not when a fault appears on site.
First articleA new design is measured and stressed against the agreed specification before tooling is signed off.
Pre-productionThe pilot batch is aged and thermally logged, so it is the process that is approved — not just a sample.
Pre-shipmentProduction units go through aging, hipot, insulation and photometric spot checks as a batch before packing.
PackagingThe actual export carton is drop-tested, so the product arrives in the condition it left in.
Data, not adjectivesResults are recorded against the order, so a performance claim can be checked rather than trusted.
One roofPhotometry, electrical safety, thermal, corrosion and packaging testing sit in the same building as production.
Fix it hereProblems are caught before packing, when a correction costs days instead of a project.

Need test data with your order?

Tell us which parameters your project or specifier requires. We will confirm what can be verified in house and include the results with your shipment.

Talk to our engineering team

Company Profile
Corporate overview & capabilities
Our Story & Culture
Our journey, values & culture
Hotel Projects & Case Studies
Hospitality lighting projects & case studies
Exhibitions
Trade fairs across Asia & Europe

Request A Quote

We will offer you the best service within 24 hours

*We respect your confidentiality and all information are protected.