Our Test Lab
Sixteen instruments. Five disciplines. One roof — so the performance we quote is the performance we ship.
We don’t estimate performance. We measure it.
In 2026 we commissioned a dedicated test laboratory at our Zhongshan factory. The equipment covers photometry and colour, electrical safety, driver and battery behaviour, reliability and aging, and environmental and transport durability — the five areas that decide whether a luminaire survives a hotel installation.
The laboratory is used for design verification on new developments, inspection of incoming drivers, LED boards and battery packs, and pre-shipment batch control on finished goods. Results are recorded against the order, so a specifier can see how the actual production units performed — not how a hand-built sample performed.
Five disciplines, under one roof.
Every instrument below is installed at our Zhongshan factory. Together they follow a product from an incoming driver to a packed export carton.
Photometric & Colour Measurement
A 2 nm bandwidth CCD spectrometer covering 380–780 nm reports the numbers a lighting designer actually works with.
- Correlated colour temperature, 1,000–100,000 K
- Colour rendering index (CRI / Ra)
- Chromaticity coordinates and SDCM colour tolerance
- Illuminance 0.1 lx – 200 klx, spectral distribution
Electrical Safety
Insulation, dielectric strength, leakage and earthing verified on assembled luminaires and drivers.
- Insulation resistance 10 V–1,000 V, 1 × 105 to 1 × 1011 Ω
- Dielectric withstand (hipot) testing
- Leakage current measurement
- Earth / ground continuity
Driver, Power & Battery
The electronics side of a luminaire, tested at the values the project will actually run at.
- Driver output voltage, current and power
- 50 Hz and 60 Hz operation, brown-out and over-voltage response
- Battery discharge capacity and internal resistance
- Over-charge, over-discharge, over-current and short-circuit protection
Reliability, Aging & Thermal
Stress applied before shipment, so early-life failures happen here instead of on site.
- Programmable high–low voltage impulse aging
- 16-channel temperature rise logging, −200 to 1,250 °C at 0.01 resolution
- Stability test bench for free-standing luminaires
Environmental & Transport
Finish performance and packaging protection for coastal projects and long-haul shipping.
- NSS, ACSS and CASS salt spray corrosion testing
- Face, edge and corner free-drop testing
- Drop height 300–1,500 mm, specimen up to 80 kg
The room behind the numbers.
Every instrument on this page — and the mechanical and surge stations working alongside them — sits in our own facility in Zhongshan. These are the actual benches.





We age it, cycle it and heat it — so your site doesn’t have to.
Most failures in a hospitality lighting project show up in the first weeks: a driver that cannot hold at a low mains voltage, a thermal hot spot inside a sealed head, a battery pack that trips on over-current after twenty cycles.
The high–low voltage impulse aging controller runs finished luminaires through repeated supply swings, while the DC6016 logger tracks sixteen thermocouple channels across drivers, LED boards and heat sinks. The stability bench then confirms that a free-standing luminaire will not topple at the specified angle.
What is in the lab.
Sixteen instruments, listed with what each one actually verifies in our production.
| Instrument | What it verifies in our production |
|---|---|
| HPS200 Handheld Spectral Color Illuminance Meter | CCT, CRI, chromaticity coordinates, SDCM colour tolerance, illuminance and spectral distribution |
| DC2679E Programmable Insulation Resistance Tester | Insulation resistance of luminaires and drivers, before and after aging |
| Dielectric Withstand (Hipot) Tester | Dielectric strength, leakage current and earth continuity on assembled fittings |
| Digital Multimeter | Voltage, current, resistance and capacitance for assembly checks and fault finding |
| DC6016 Multi-Channel Temperature Logger | Temperature rise on drivers, LED boards and heat sinks; instrument range −200 to 1,250 °C, 0.01 resolution, K-type thermocouples supplied |
| ZLT-WD1 Stability Test Bench | Toppling resistance of floor and table luminaires at the specified tilt angle |
| Salt Spray Test Chamber (60A) | NSS, ACSS and CASS corrosion resistance of plated, painted and anodised finishes |
| Single-Arm Drop Test Machine | Face, edge and corner drops; packaging protection under transport shock |
| Seven-Meter High-Precision Test Bench | Driver output voltage, current and power measured against specification |
| Adjustable DC Power Supply | Low-voltage LED board function and current draw |
| Variable Frequency AC Power Source | Operation on 50 Hz and 60 Hz supplies; power consumption verification |
| Variable Transformer (Variac) | Driver start-up and hold at low and high mains voltage; aging power supply |
| Programmable Battery Comprehensive Tester | Battery discharge capacity and internal resistance; driver output-side parameters |
| Battery Comprehensive Tester | Battery voltage and internal resistance; over-charge, over-discharge, over-current and short-circuit protection |
| High-Low Voltage Impulse Aging Test Control Box | Driver endurance under repeated mains voltage swings; early-life failure screening |
| USB Power Tester | USB charging voltage, current and power; cumulative energy and charge capacity |
Methods that trace back to published standards.
Where a published method exists for a test we run, our parameters are configured to it.
Photometric & colour measurement
CCT, CRI / Ra, chromaticity coordinates, SDCM and illuminance measured with a 2 nm bandwidth CCD spectrometer over 380–780 nm.
Dielectric withstand, insulation & earthing
Dielectric strength, leakage current and earth continuity verified on assembled luminaires, drivers and metal-bodied fittings.
Thermal & temperature rise
Sixteen-channel K-type thermocouple logging at 0.01 resolution, recording live values, temperature-rise values and real-time curves.
Corrosion (salt spray)
NSS, ACSS and CASS cycles; chamber at 35 ±1 °C and CASS at 50 ±1 °C with a 47 ±1 °C air saturator, parameters set to JIS, ASTM, CNS and GB standard values.
Transport packaging drop
Face, edge and corner free-drop tests with encoder-verified drop height, configured to ISO 2248, JIS Z 0202-87 and GB/T 4857.5-92.
Voltage stress & battery protection
Programmable high–low voltage impulse cycling in automatic and manual modes, plus battery over-charge, over-discharge, over-current and short-circuit threshold testing.
Five checkpoints between your specification and your shipment.
Need test data with your order?
Tell us which parameters your project or specifier requires. We will confirm what can be verified in house and include the results with your shipment.